Master Harstra machine servicing in 1 day – SIGN UP HERE
Key features:
K6 – Multi-PPE Drying Cabinet
The K6 drying cabinet is a wide and versatile dryer, made for drying protective clothing and small PPE items. With space for 6–9 coats or pants—and room for optional frames—it offers more flexibility than the compact K3. Place the wet gear inside and let the drying cabinet do the work. Built-in sensors detect when the PPE is fully dry and shut the system off automatically. The automatic drying cycle takes approximately 2 hours. Time-based drying is also available.
The main advantage of a drying cabinet compared to a tumble dryer is the significantly reduced wear and tear.
Can dry
Cannot dry
Before drying
Only place protective clothing and small PPE in the cabinet after the items have been properly cleaned and disinfected. The K6 is designed for drying only.
About the K-series
Recommendations
For drying SCBAs, choose the M45B.
For a mix of turnout gear and small PPE items, choose the K6.
For dedicated small-PPE drying, use the M18 (compact) or M45 (large).
For drying a combination of SCBAs and small PPE, consider the F12 or M45B.
| Dimensions | height x width x depth in mm |
| External | 2120 x 1260 x 730 |
| Internal | 1800 x 1200 x 600 |
| Content | 1296 liter |
| Net weight | 250 kg. |
| External | Stainless steel |
| Internal | Stainless steel |
| Coating | RAL 9016 |
| Doors | 2 piece |
| Door sealing | magnetic strip |
| Drip tray | polished stainless steel |
| Adjustable legs | 4 pieces., adjustable for stability and spirit level |
| Insulation | glass wool, min. 30 mm thick |
| Temperature range | up to 58C. set at 40C. by manufacturer |
| Second temperature | self-adjustable |
| Temperature reading | digital LED reading |
| Expiring time clock | digital LED reading, set between 1 minute and 99:58 hours |
| Electronic temperature control | 2 pieces PTC sensors, solid state relay |
| Electronic moisture measure | capacitive sensor |
| Temperature safeguard | extra thermostat (max. 60˚C.) |
| Heating | direct heating, approx. 2 kW |
| Air circulation | by means of 2 low-noise ventilator |
| Air refreshment | by air outlet on top of the cabinet, PVC tube of Ø 32 mm |
| Air inlet | at bottom of the cabinet through a filter |
| Filter | Class F5, EN 779 |
| Capacity | maximum 6 to 9 coats or trousers |
| Clothes rail | 1 piece, stainless steel and removable |
| Drying time | approx. 4 hours |
| Mains connection | 230 Volt AC, N + PE, 50-60 Hz. |
| Power | approx. 2,2 kW, secured 1 x 16 Ampere |
| Electricity consumption | average 0,8 kWh |
Compare models to find the best fit for your station